6.10 Light steel framed walls and floors

6.10.14 Behaviour in relation to fire

LSF walls and floors shall be in accordance with applicable Building Regulations.

Guidance within supporting documents to the Building Regulations should be fully considered in the design and construction of LSF walls, floors and roofs.

Detailing and specification of components should be in accordance with the steel frame manufacturer’s recommendations and/or guidance from SCI (see guidance in P424 'Light steel framing in fire') and supported with representative test evidence to appropriate standards such as BS 476:21 or BS EN 1365:1 for load-bearing walls, BS 476:22 or BS EN 1364:1 for infill walls and BS EN 1365:2 for floors.

The performance of specific details should be taken into account, including:

  • fire protection to the structure around openings
  • detailing of cavity barriers, including moisture protection to the barrier
  • detailing around service penetrations
  • compartmentation including interfaces with fire doors.