4.2.12 Method of assessment of foundation depths using charts
Foundation depths shall be determined to prevent excessive movement due to ground heave.
A detailed method of assessing foundation depths of up to 2.5m using Charts 1-3 are given in the worked Example of clause 4.2.14 of this chapter.
Table 10 can be used in determining the D/H ratio needed for use within the charts, where:
D is the distance measured from the centre of the trees or hedgerows to the face of the foundation and
H is the appropriate height of trees (mature or actual, depending on what is being assessed).
Last updated: 3rd January 2024