6.3.10 Construction of steel framed partitions
Non load-bearing steel framed walls shall be suitably constructed.
Noggings or straps should be provided as required to support fittings, such as radiators, wall-mounted boilers, sanitary fittings and kitchen units, etc. Non load-bearing partitions should not be wedged against floor joists, ceiling joists or roof trusses. Allowance should be made for floors, ceilings or roofs to deflect as necessary, so that the partition does not become load-bearing, in accordance with the design. They should be:
- constructed in accordance with manufacturers’ requirements and the design
- correctly positioned, square and plumb
- supported on a structural floor, but not a floating floor that incorporates a compressible layer, unless specifically designed for that purpose
- fixed to the floor at the head, to each other and to abutting walls
- provided with extra studs at openings where required
- finished in accordance with Chapter 9.2 Wall and ceiling finishes.