Also see:
6.611.3.13 Staircases
Staircases shall comply with the Technical Requirements and be designed to ensure adequate safety and performance.
Staircases should be designed, specified, and installed in accordance with Chapter 6.6 Staircases.
Wall linings should be continuous behind the string of staircases.
Fixing connections should be coordinated to ensure fire protection continuity and structural adequacy.
Where staircases are factory installed into volumetric units, consideration should be given to construction tolerances and the potential for differential vertical movement when designing connections to upper units. Landings should be framed to provide full support and solid fixings for the tops of flights, nosings, newels, apron linings, etc.
Suitable access should be provided to facilitate final installation of staircases and connection to upper units on site, including any necessary fixings or supports required.
The top nosing of staircases should be:
- level with the floor decking
- fixed firmly.